Introduction

In Vaniyambadi, one of India’s largest leather-tanning centers, the VANITEC common effluent treatment plant (CETP) collects and treats effluent from participating tanneries, recovering water for reuse through a two-stage reverse osmosis (RO) system. The RO system was built 15 years ago with an Energy Recovery hydraulic turbocharger, which recovered energy from RO reject that would otherwise have been wasted, making the system energy-efficient and sustainable. This forward-thinking approach positioned the initial adopters as early industry leaders, setting a benchmark that resonated across the globe.
Location
Vaniyambadi, Tamil Nadu, India
Project
VANITEC CETP
Feed Salinity
18,000 to 25,000 ppm TDS
Energy Savings
~25% reduction in SEC (2.87 to 2.15 kWh/m3)
Recovery Rate
65% (permeate / feed)
The Challenge
Over the system’s 15 years of reliable service, the effluent grew saltier, with feed salinity expected to range from 18,000 ppm to 25,000 ppm total dissolved solids (TDS) and drive higher osmotic pressure. The second RO stage now required far more interstage boost: 39 m³/h at 20 bar, up from 29 m³/h at 13 bar. VANITEC needed a drop-in retrofit that could restore the required boost and lower energy use at the same time.
The Solution
AT 250 Turbocharger: A Drop-In Energy Recovery Retrofit for Rising Salinity
To address the higher feed salinity and reduce energy use cost-effectively, VANITEC selected the Energy Recovery AT 250 turbocharger.
Key elements of the retrofit included:
- Replacement of the plant’s existing energy recovery device within the current RO skid, restoring full second-stage performance with minimal capital cost or downtime
- Sizing to deliver the higher interstage boost that rising feed salinity demanded
- Installation of one AT 250 turbocharger on each of the three RO trains, commissioned in January 2026
The approach aligned with VANITEC’s goal of sustaining its water reuse rate and lowering lifecycle operating costs while adapting a proven system to tougher feedwater conditions.
After 15 years of reliable operation, rising salinity meant our RO system needed more boost than it was originally designed to deliver. Energy Recovery’s AT 250 turbocharger dropped seamlessly into our existing skid, restored the second-stage pressure, and cut our energy use by roughly a quarter. Six months of operation have confirmed the result.
-H. Nazeer Ahmed, Plant Manager, VANITEC
The Result
1
Specific energy consumption (SEC) reduced from 2.87 to 2.15 kWh/m³, a reduction of roughly 25%
2
Saved approximately 648 kWh/day per train, or about 226,800 kWh/year per train, delivering a simple payback of well under two years
3
Restored full second-stage performance without upsizing or replacing the existing feed pump, sustaining the plant’s 65% recovery and water reuse rate with minimal capital cost or downtime
Why It Matters
These results show how a well-matched energy recovery device can adapt an existing RO system to harsher, higher-salinity conditions, turning pressure energy that was previously wasted into lower operating costs, without a capital-intensive system upgrade.
VANITEC’s retrofit is a blueprint for high-salinity industrial water reuse: proof that a plant can meet rising treatment demands and cut energy use at the same time, using its existing infrastructure. As industrial operators across India and beyond face saltier effluent, tighter discharge limits, and higher energy costs, Energy Recovery is applying the expertise it built as the leader in seawater desalination to help customers improve efficiency in high-pressure industrial water reuse applications.